Harmonics hit harder than their size.
Winding eddy loss grows with the square of harmonic order. A modest 5th and 7th harmonic content can add far more heat than the RMS current suggests. That heat is what drives the hotspot.
Patent pending: US 19/738,513
Load grows, harmonics from drives, inverters and server power supplies stack on top, and the hotspot climbs. You derate, shed load, or order a replacement that costs seven figures installed, and the delivery date keeps moving. If the old unit fails before the new one shows up, you pay for a mobile unit, overtime and an outage you cannot schedule.
Everyone is trying to monitor the transformer better, or get a better place in the transformer line.
Winding eddy loss grows with the square of harmonic order. A modest 5th and 7th harmonic content can add far more heat than the RMS current suggests. That heat is what drives the hotspot.
Every time a magnetic field collapses, that stored energy has to go somewhere. Conventional designs suppress it or burn it off as heat. Put it back to work and the same job runs with less loss. Same energy in, less of it wasted.
Insulation life falls off exponentially with hotspot temperature. Roughly every 6 to 7 °C off the hotspot halves the aging rate. Take loss out and the transformer lives longer without a rewind.
Defaults are placeholders. Put in your own figures. This is the loss, replacement and waiting spend ModFormer goes after. Bring the number to the fit review. See modeled loss on live grid nodes at kvolt.io.
You send your transformer ratings, load profiles, harmonic sources and the temperatures you see. We tell you whether it fits. No charge, under mutual NDA.
Fixed fee. We model your units against your load profiles under IEEE C57.91 and size the module. You get an installation plan and a firm quote. The fee is credited to your order.
We build a unit for your transformer. You set the acceptance test. Payment at milestones, not up front.
Supply for your fleet, or a field-of-use license if you build it yourself.
| Parameter | Current status / specification |
|---|---|
| Patent status | Patent pending. US nonprovisional application 19/738,513, claiming priority to a provisional filed 12 Jul 2025. |
| Readiness | Built to order. Design complete. Schematics and fab-ready board files complete; modeled against IEEE C57.91. Custom built to your units; your qualification unit is the first build. |
| Architecture | Runs on our timing firmware and dedicated hardware. |
| Fits | Oil-immersed distribution transformers: industrial, data center, solar integration and utility fleets. |
| Install | In parallel with the existing transformer. Not opened, not rewound. Remove it and you are back to normal operation. |
| Protection | Relay settings, fuse coordination and protection schemes unchanged. |